HyperbolicTangent#

Description#

HyperbolicTangent (registered sub-model keyword: hyperbolicTangent) is a Locate Models sub-model used in coupled CFD-DEM simulations.

  • Category: Locate Models

  • Registered Keyword: hyperbolicTangent

  • Applicable Solvers: resolvedDiffuseInterfaceLAMMPSFoam

Smooth hyperbolic tangent indicator transition function for spherical particles.

Mathematical Formulation#

HyperbolicTangent constructs a smooth solid volume fraction field \(\alpha_s(\mathbf{x})\) and solid particle velocity field \(\mathbf{U}_p(\mathbf{x})\) across grid cell centers using a hyperbolic tangent interface profile based on the signed distance to particle surfaces.

For a spherical particle \(i\) with radius \(R_i\) centered at position \(\mathbf{x}_i\):

  1. Signed Distance Function:

    \[\phi(\mathbf{x}, \mathbf{x}_i) = \|\mathbf{x} - \mathbf{x}_i\| - R_i\]

    where \(\phi < 0\) inside the particle, \(\phi = 0\) on the particle surface, and \(\phi > 0\) outside the particle.

  2. Solid Volume Fraction Field:

    \[\alpha_s(\mathbf{x}) = \frac{1}{2} \left[ 1 - \tanh\left( \frac{\phi(\mathbf{x}, \mathbf{x}_i)}{\delta} \right) \right]\]

    where \(\delta\) is the interface thickness parameter (configured via thicknessParameter).

    Note

    The actual interface thickness computed becomes approximately 4 times the specified thickness parameter (\(\delta\)).

  3. Solid Velocity Mapping:

    \[\mathbf{v}_{\text{particle}, i}(\mathbf{x}) = \mathbf{v}_i + \boldsymbol{\omega}_i \times (\mathbf{x} - \mathbf{x}_i)\]
    \[\mathbf{U}_p(\mathbf{x}) = \frac{\sum_i \alpha_{s, i}(\mathbf{x}) \, \mathbf{v}_{\text{particle}, i}(\mathbf{x})}{\sum_i \alpha_{s, i}(\mathbf{x}) + \epsilon_{\text{small}}}\]

    where \(\mathbf{v}_i\) is the particle translational velocity and \(\boldsymbol{\omega}_i\) is the angular velocity.

Configuration#

To configure hyperbolicTangent, specify the model keyword under subModels in constant/kinematicCloudProperties or constant/solidProperties:

locateModel              hyperbolicTangent;

hyperbolicTangentCoeffs
{
    thicknessParameter   0.075;
}

Parameters#

  • thicknessParameter: Solid-fluid interface thickness parameter delta.