gran scaling model#
Syntax#
Append /scaling to compatible pair gran models
Examples#
pair_style gran model hertz/scaling tangential history/scaling cohesion liquid/Newtonian/scaling capillaryNormalLambert on viscousNormalWashino on viscousTangentWashino on modifyLbVolume on
pair_style gran model simplifiedJKR/scaling tangential history/simplifiedJKR/scaling cohesion liquid/Newtonian/scaling rolling_friction marshall/scaling viscousNormalWashino on viscousTangentWashino on modifyLbVolume on
Description#
This adds the following scaling models to compatible pair gran and fix wall/gran models as listed below.
Scaled-up particle model - when employing artificially larger particle size in order to reduce the number of particles.
Reduced particle stiffness (RPS) model - when employing artificially reduced particle stiffness (‘softer particles’) which enables larger simulation timestep to be used.
These are commonly used approaches to reduce computational times. However, changing these parameters can directly influence the behaviour and dynamics of the system. Hence, the forces and torque have to be appropriately ‘adjusted’ or scaled to maintain similar behaviour as the original system. More details of the models are given below.
Scaled-up particle model#
The scaling criteria can be generally divided into two categories, i.e., for (i) inter-particle and (ii) body type forces. These are derived based on the continuum assumption, to maintain (i) the stress due to inter-particle force and (ii) momentum source due to body force in a control volume between the scaled-up and original particle systems. A summary of the force and torque scaling is given in the table below.
Type of force/torque |
Force scaling |
Torque scaling |
|---|---|---|
Inter-particle (e.g., contact, attraction) |
\(\pmb{F}_{i,S} = \xi^2\pmb{F}_{i,O}\) |
\(\pmb{M}_{i,S} = \xi^2\pmb{M}_{i,O}\) |
Body (e.g., gravity, fluid force) |
\(\pmb{F}_{b,S} = \xi^3\pmb{F}_{b,O}\) |
NA |
Others (rolling resistance) |
NA |
\(\pmb{M}_{i,S} = \xi^2\pmb{M}_{i,O}\) |
The particle size scale factor \(\xi\) is given as follow. \(d_p\) is the particle diameter while subscripts \(_S\) and \(_O\) refer to the scaled-up and original particles respectively.
In order to compute the original particle force and torque, the original particle properties/parameters have to be used or calculated from the scaled-up particles. A summary of the parameter relationship is given below. Geometric similarity is also applied to the particle overlap, separation distance (for negative overlap forces) and liquid bridge rupture distance (for liquid bridge force).
Parameter/variable |
Relationship |
|---|---|
Particle diameter |
\(d_{p,O} = d_{p,S}/\xi\) |
Particle mass |
\(m_O = m_S/\xi^3\) |
Translational velocity |
\(\pmb{v}_O = \pmb{v}_S\) |
Rotational velocity |
\(\pmb{\omega}_O = \xi \pmb{\omega}_S\) |
Particle overlap, normal |
\(\delta_{n,O} = \delta_{n,S}/\xi\) |
Particle overlap, tangential |
\(\delta_{t,O} = \delta_{t,S}/\xi\) |
Liquid bridge volume |
\(V_{lb,O} = V_{lb,S}/\xi^3\) |
Liquid bridge rupture distance |
\(S_{rup,O} = S_{rup,S}/\xi\) |
Separation distance |
\(S_O = S_S/\xi\) |
Reduced particle stiffness (RPS) model#
Generic scaling criteria are derived for attraction forces and rolling resistance based on the dimensionless equation of motion, i.e., to maintain the particle motion between the reduced and original particle stiffness systems in the dimensionless time and space during contact. A summary of the force and torque scaling is given in the table below. Generally, the scaling differs depending on the contact model used (linear or non-linear spring dashpot model).
Type of force/torque |
Model |
Force scaling |
Torque scaling |
|---|---|---|---|
Contact |
Hertz, Hooke etc. |
No scaling required |
No scaling required |
Attraction-linear (a) |
Liquid bridge (c) |
\(\pmb{F}_{lb,R} = \sqrt{\Omega_k}\pmb{F}_{lb,O}\) |
No scaling required |
Attraction-non-linear (b) |
Liquid bridge (c) |
\(\pmb{F}_{lb,R} = \Omega_E^{2/5}\pmb{F}_{lb,O}\) |
No scaling required |
Attraction-non-linear (b) |
JKR adhesion force |
\(\gamma_R = \Omega_E^{2/5}\gamma_O\) |
No scaling required |
Rolling resistance-linear (a) |
CDT, EPSD |
NA |
No scaling required |
Rolling resistance-non-linear (b) |
CDT, EPSD |
NA |
No scaling required |
Rolling resistance-non-linear (b) |
AR |
NA |
\(\pmb{M}_{R,R} = \Omega_E^{2/5}\pmb{M}_{R,O}\) |
(a) when linear contact model (e.g., Hooke) is used (b) when non-linear contact model (e.g., Hertz) is used (c) includes capillary, normal viscous and tangential viscous forces
The reduction ratios \(\Omega_k\) and \(\Omega_E\) for the spring constant \(k_c\) and Young’s modulus \(E_c\) are given as follow. Subscripts \(_R\) and \(_O\) refer to the reduced and original stiffness respectively.
Currently the scaled-up particle and RPS models are implemented in the following models:
Type of force/torque |
pair gran model |
Description |
|---|---|---|
Contact force & torque |
model hooke/scaling |
Linear Hookean contact model |
Contact force & torque |
model hertz/scaling |
Non-linear Hertzian contact model |
Contact force & torque |
tangential history/scaling |
Tangential force of the Hookean/Hertzian contact model |
Contact force & torque |
Luding elasto-plastic-adhesive contact model |
|
Contact force & torque |
Tangential force of the Luding contact model |
|
Contact force & torque |
Simplified JKR model for adhesive contacts |
|
Contact force & torque |
Tangential force of the simplified JKR model |
|
Contact force & torque |
Full JKR model for adhesive contacts |
|
Contact force & torque |
Tangential force of the full JKR model |
|
Attraction force & torque |
Liquid bridge model for Newtonian fluids |
|
Attraction force & torque |
Liquid bridge model for non-Newtonian power law fluids |
|
Rolling resistance torque |
rolling_friction cdt/scaling |
CDT rolling friction model |
Rolling resistance torque |
rolling_friction epsd2/scaling |
EPSD2 rolling friction model |
Rolling resistance torque |
AR rolling friction model |
(a) includes contact and attraction force and torque
For the scaled-up particle model’s body force scaling, gravity is already inherently scaled by \(\xi^3\) from the particle mass, and does not require any modification.
Note
Currently, the following gran models: model simplifiedJKR/scaling, tangential history/simplifiedJKR/scaling, model JKR/scaling, tangential history/JKR/scaling, cohesion liquid/Newtonian/scaling, cohesion liquid/powerLaw/scaling and rolling_friction marshall/scaling are only available with scaling.
Note
The RPS model is not yet applied to model luding/scaling and tangential tan_luding/scaling.
Initialisation#
This model requires several additional model parameters to be defined. The parameter scaleFactor is the particle size scale factor \(\xi\) in Eqn 1. The parameter scalePowerIndex refers to the index \(m\) in \(\xi^m\) in the scaled-up particle model table. Generally, it should be 2 for all inter-particle force/torque. The parameter rpsFactor refers to the RPS model scaling coefficient. This depends on the combination of models selected. Generally, rpsFactor = \(\sqrt{\Omega_k}\) or \(\Omega_E^{2/5}\) for linear or non-linear contact models respectively, where \(\Omega_k\) and \(\Omega_E\) are the stiffness reduction ratios in Eqn 2 and Eqn 3.
Scaled-up particle model properties:
fix id all property/global scaleFactor scalar value # (value=value for particle size scale factor (=scaled-up/original particle size), optional, default: 1.0) fix id all property/global scalePowerIndex scalar value # (value=value for scaled-up particle model power index, optional, default: 2.0)
Reduced particle stiffness (RPS) model properties:
fix id all property/global rpsFactor scalar value # (value=value for rps scale factor, optional, default: 1.0)
Note
The scaling properties (scaleFactor, scalePowerIndex, and rpsFactor) are optional in WASHLIGGGHTS. If omitted, default values (1.0, 2.0, and 1.0 respectively) are automatically used.
Symbol list#
\(d_p\): Particle diameter (m)
\(E_c\): Young’s modulus (Pa)
\(\pmb{F}_b\): Body force (N)
\(\pmb{F}_i\): Inter-particle or particle-wall force (N)
\(\pmb{F}_{lb}\): Liquid bridge force (N)
\(k_c\): Spring constant (N/m)
\(m\): Particle mass (kg)
\(\pmb{M}_i\): Inter-particle or particle-wall torque (N.m)
\(\pmb{M}_R\): Rolling resistance (torque) (N.m)
\(S\): Inter-particle or particle-wall separation distance (m)
\(S_{rup}\): Liquid bridge rupture distance (m)
\(\pmb{v}\): Particle translational velocity (m/s)
\(V_{lb}\): Liquid bridge volume (m3)
\(\gamma\): Surface energy (J/m2)
\(\delta_n\), \(\delta_t\): Inter-particle or particle-wall normal and tangential overlap (m)
\(\xi\): Particle size scale factor (-)
\(\pmb{\omega}\): Particle rotational velocity (rad/s)
\(\Omega_E\), \(\Omega_k\): Stiffness (Young’s modulus and spring constant) reduction factor (-)
Default#
scaleFactor = 1.0
scalePowerIndex = 2.0
rpsFactor = 1.0