fix mesh/surface/stress#

Syntax#

fix ID group-ID mesh/surface/stress file filename premesh_keywords premesh_values mesh_keywords mesh_values surface_keyword surface_values stress_keywords stress_values
  • ID, is documented in fix command, the group-ID is ignored for this command

  • mesh/surface/stress = style name of this fix command

  • file filename premesh_keywords premesh_values mesh_keywords mesh_values surface_keyword surface_values are documented in fix mesh/surface.

  • zero or more stress_keyword/value pairs may be appended

  • stress_keyword = reference_point, stress, wear or t_lowpass

    • reference_point values = rx ry rz

      • rx ry rz = coordinates of reference point

    • stress value = on or off

    • wear value = finnie or off

    • t_lowpass value = cutoff

      • cutoff = cutoff period (time units)

Examples#

fix cad all mesh/surface/stress file mesh.stl type 1 wear finnie
fix cad all mesh/surface/stress file mesh.stl type 1 t_lowpass 1e-3

Description#

This fix is identical to fix mesh/surface but additionally the average normal and shear stresses that the particles in the fix group exert on each triangle of the mesh is evaluated (which costs a bit of performance). Also, the total force and torque on the mesh is calculated (see output info). The per-element average normal stress can be dumped into VTK format using dump mesh/vtk.

With the optional stress keyword, stress tracking can be turned off if desired. The reference point for calculating the body torque can be controlled via the reference_point keyword. The optional wear keyword can activate a simple qualitative wear model (finnie) - for details on the model, see the seperate /doc/finnie-wear.pdf. The finnie constant k in Eqn. (4.23) has to be specified as follows:

fix id all property/global k_finnie peratomtypepair n_atomtypes value_11 value_12 .. value_21 value_22 .. .
# (value_ij=value for the finnie constant between atom type i and j; n_atomtypes is the number of atom types you want to use in your simulation)

The optional t_lowpass keyword applies a low-pass filter to the computed total force and torque on the mesh, which smooths out highly fluctuating values. For example, this is useful for cases with hard particles where the contact duration is small. The cutoff period (time below which the values are filtered) is specified.

Restart, fix_modify, output, run start/stop, minimise info#

This fix stores a global vector with 9 components for access by various output commands. The first 3 components are equal to the total force on the mesh, the next 3 components store the total torque on the body exerted by the particles. Finally, the last 3 components are the coordinates (moved, scaled, rotated) of the reference point.

Default#

reference_point = 0. 0. 0., stress = on, wear = off, t_lowpass = 0.001*timestep