gran cohesion liquid/powerLaw/scaling model#
Syntax#
cohesion liquid/powerLaw/scaling [other model_type/model_name pairs as described here] keyword values
Zero or more keyword/value pairs may be appended to the end (after all models are specified):
capillaryModel = capillaryNormalLambert or capillaryNormalRabinovich
capillaryNormalLambert or capillaryNormalRabinovich value = on or off
on = enables the model (default: capillaryNormalLambert is on if no capillary normal model is specified)
off = disables the model
powerLawViscousNormalModel = powerLawViscousNormalWashino
powerLawViscousNormalWashino value = on or off
on = enables the model (default: powerLawViscousNormalWashino is on if no normal viscous model is specified)
off = disables the model
powerLawViscousTangentModel = powerLawViscousTangentWashino
powerLawViscousTangentWashino value = on or off
on = enables the model (default: powerLawViscousTangentWashino is on if no tangential viscous model is specified)
off = disables the model
liquidTransferModel = liquidTransferSimple
liquidTransferSimple value = on or off
on = enables the model
off = disables the model
limitLiquidContent value = on or off
on = enables the model parameter maxLiquidContent
off = standard implementation without a limiter for the per particle liquid content
modifyLbVolume value = on or off
on = enables the model parameter lbVolumeFraction
off = standard implementation with lbVolumeFraction = 0.05
tangential_reduce value = on or off
on = tangential model does not see normal force computed by this model
off = tangential model does see normal force computed by this model
Examples#
pair_style gran model hertz/scaling tangential history/scaling cohesion liquid/powerLaw/scaling capillaryNormalLambert on powerLawViscousNormalWashino on powerLawViscousTangentWashino on modifyLbVolume on
pair_style gran model simplifiedJKR/scaling tangential history/simplifiedJKR/scaling cohesion liquid/powerLaw/scaling rolling_friction marshall/scaling powerLawViscousNormalWashino on powerLawViscousTangentWashino on modifyLbVolume on
pair_style gran model hertz/scaling tangential history/scaling cohesion liquid/powerLaw/scaling modifyLbVolume on
Description#
This model can be used as part of pair gran and fix wall/gran to add a liquid bridge force for a non-Newtonian power-law fluid, to a pair of particles or particle and wall, due to surface liquid film on the particles. It also solves for the transfer of surface liquid from one particle to the other as the bridge breaks up.
The liquid bridge force consists of capillary (normal component and rolling resistance torque) and viscous (normal and tangential components) contributions; the former due to surface tension and the latter due to liquid viscosity and relative motion of particles. Different models for each of these components can be selected:
For the capillary force, capillaryNormalLambert and capillaryNormalRabinovich are both commonly used capillary force models for pendular liquid bridges (defaults to capillaryNormalLambert if omitted).
For the normal and tangential viscous forces, powerLawViscousNormalWashino and powerLawViscousTangentWashino introduce closed-form solutions for pendular liquid bridge of non-Newtonian power-law fluid, i.e., fluid which viscosity changes with shear rate (both default to on if omitted).
For surface liquid transfer, liquidTransferSimple redistributes the liquid based on the volume ratio of the particle pair.
This model also includes (i) scaled-up particle and (ii) reduced particle stiffness (RPS) models to maintain the similar behaviour as the original system when employing artificially (i) larger particle size and/or (ii) smaller particle or wall stiffness, in order to reduce computational times. Refer to gran scaling model for the model description and scaling parameters.
Bridge formation, breakage and surface liquid transfer model:#
A liquid bridge is formed when two particles (or particle and wall) first come into contact where \(\delta\) is the overlap:
The volume of the liquid bridge formed is given by:
lbVolumeFraction is given as a model parameter while \(V_{l,i}\) and \(V_{l,j}\) are the surface liquid volume of particles i and j. The initial surface liquid amount is specified by the model parameter surfaceLiquidContentInitial.
The bridge breaks when the particle (or particle-wall) separation distance \(S\) exceeds the rupture distance \(S_{rup}\) as given below. \(\theta\) is the effective contact angle between solid and liquid.
When the bridge breaks, the liquid is redistributed to the particles depending on the specified liquidTransferModel. The only option currently is liquidTransferSimple, where liquid is redistributed based on the volume ratio of the particle pair. The split factor of the liquid bridge is given as:
Per default, this model automatically instantiates a scalar transport equation that solved for the surface liquid content of each particles, expressed in % of particle volume. The surface liquid volume is assumed to be small, i.e., it is assumed to have no effect on the particle mass, diameter and density. From the split factor, the surface liquid volume flux for particles i and j (in terms of % particle volume) are then calculated as follow. \(\Delta_t\), \(V_{par,i}\) and \(V_{par,j}\) are the simulation timestep and particle volumes.
Note
There is currently no liquid transfer between particle and wall.
Capillary force:#
The generic form of the capillary force can be expressed as follow. \(C_{cap}\) is a lumped coefficient related to the liquid bridge properties while \(\pmb{n}\) is the unit normal vector between particle (or particle-wall) centres.
For capillaryModelLambert, the coefficient \(C_{cap}\) is given as:
For capillaryModelRabinovich, the coefficient \(C_{cap}\) is given as:
\(\overline{r}\) is the reduced radius, while \(\sigma\) and \(\theta\) are the liquid surface tension and effective contact angle between solid and liquid. \(h\) and \(\alpha\) are the liquid bridge immersion height and filling angle which are calculated as follow:
During contact, \(S\) is taken as 0.
Normal viscous force for power-law fluid:#
The liquid used for the bridge is a power-law fluid and the viscosity can be given as follow. \(\dot{\gamma}\) is the shear rate of the liquid while \(K\) and \(n\) are the flow consistency and power-law index.
The generic form of the normal component of the viscous force is then expressed as follow. \(C_n\) is a lumped coefficient related to the liquid bridge properties for power-law fluid while \(\pmb{v}_{r,n}\) is the translational relative velocity in the normal direction.
\(\pmb{v}_{r,n}\) is computed from the velocities of particles i and j (\(\pmb{v}_i\), \(\pmb{v}_j\)) and the unit normal vector \(\pmb{n}\):
For powerLawViscousNormalWashino, the coefficient \(C_n\) can be written as:
\(f_{Lian}\) is given as follow:
\(c\), \(N\) and \(\Omega\) are parameters given as follow:
where \(b\) is the liquid bridge radius:
The viscous force tends to infinity as the separation distance \(S\) approaches zero. Therefore, a minimum separation distance \(S_{min}\) is applied, which is specified by the model parameter minSeparationDistanceRatio (\(=S_{min}/\overline{r}\), where \(\overline{r}\) is the particle or particle-wall reduced radius). The same applies to the tangential viscous force model described below.
Tangential viscous force for power-law fluid:#
The generic form of the tangential viscous force can be expressed as follow. \(C_{t,T}\) and \(C_{t,R}\) are coefficients for translational and rotational components of the tangential viscous force, which are related to the liquid bridge properties for power-law fluid. \(\pmb{v}_{r,t}\) and \(\pmb{\omega}_r\) are the translational relative velocity in the tangential direction and the rotational relative velocity.
\(\pmb{v}_{r,t}\) and \(\pmb{\omega}_r\) are computed as follow. \(r_i\), \(r_j\), \(\pmb{\omega}_i\) and \(\pmb{\omega}_j\) and the radii and rotational velocities of particles i and j.
For powerLawViscousTangentWashino, the coefficients \(C_{t,T}\) and \(C_{t,R}\) can be written as:
where \(f_T\) and \(f_R\) are given as:
\(c\), \(\lambda\), \(b^*\), \(A_T\) and \(A_R\) are parameters given as follow:
where \(b\) is the liquid bridge radius as given in the normal viscous force section above and \(\chi\) is given as:
Additionally, the torque due to the viscous force is given as follow:
\(\pmb{F}_{v,tq}\) is the component of the viscous force that contributes to the particle rotation, which is calculated as below. \(C_{tq,T}\) and \(C_{tq,R}\) are translational and rotational coefficients which are related to the liquid bridge properties.
For powerLawViscousTangentWashino, the coefficients \(C_{tq,T}\) and \(C_{tq,R}\) can be written as:
where \(f_T\) and \(f_R\) are given as:
The parameters \(c\), \(b^*\), \(A_T\) and \(A_R\) are calculated as described previously.
Capillary torque (rolling resistance):#
The model incorporates a capillary torque model based on Marshall (2014), extended to non-Newtonian power-law fluids by using the macroscopic shear rate. The torque opposes the relative rolling/rotational motion of contacting or close particles connected by a liquid bridge.
The capillary number \(\text{Ca}\) for the power-law fluid is defined based on the flow consistency \(K\), power-law index \(n\), effective particle radius \(\overline{r}\), liquid surface tension \(\sigma\), and the magnitude of the relative rotational velocity \(|\pmb{\omega}_r|\):
where \(\pmb{\omega}_r = \pmb{\omega}_i - \pmb{\omega}_j\) (or \(\pmb{\omega}_i\) for wall contact).
The torque lever arm \(\xi\) is given by:
where \(C_{\text{capTorque}}\) is the capillary torque coefficient (capillaryTorqueCoeff, default: 1.05), \(f_{\text{limit}}\) is the limit factor (capillaryTorqueLimitFactor, default: 0.13), and \(m\) is the power-law index (capillaryTorquePowerLawIndex, default: 0.45).
The capillary torque magnitude is:
and the capillary torque vector opposing relative rotation is:
During the contact phase (overlap \(\delta \ge 0\)), the capillary torque is scaled by both the RPS factor and coarse-graining factor (\(rpsFactor \cdot scaleFactor^{scalePowerIndex}\)). During the non-contact phase (liquid bridge separation without solid overlap), it is scaled by \(scaleFactor^{scalePowerIndex}\).
Initialisation#
This model requires additional parameters to be defined as given below. maxLiquidContent and/or lbVolumeFraction are required if limitLiquidContent and/or modifyLbVolume are set to ‘on’ respectively. maxSeparationDistanceRatio is used to apply a cut-off to the liquid bridge force. With the calculated liquid bridge rupture distance \(S_{rup}\), this gives a cut-off criteria = \(\text{min}\left\lbrack S_{rup}, maxSeparationDistanceRatio*\overline{r} \right\rbrack\).
Liquid bridge properties:
fix id all property/global minSeparationDistanceRatio scalar value # (value=value for the minimum separation distance (=separationDistance/rEff)) fix id all property/global maxSeparationDistanceRatio scalar value # (value=value for the maximum separation distance, recommended as 1.1) fix id all property/global surfaceLiquidContentInitial scalar value # (value=value for the initial surface liquid volume in % of particle volume) fix id all property/global surfaceTension scalar value # (value=value for the surface tension of liquid (SI units N/m)) fix id all property/global flowConsistency scalar value # (value=value for the flow consistency of the power-law fluid (SI units Pa.s^n)) fix id all property/global powerLawIndex scalar value # (value=value for the the power-law fluid index, 1=Newtonian fluid) fix id all property/global contactAngle peratomtype value_1 value_2 ... # (value_i=value for contact angle of particle type i and liquid (units degree)) fix id all property/global maxLiquidContent peratomtype value_1 value_2 ... # (value_i=value for maximum liquid content of a particle of type i in % of particle volume) fix id all property/global lbVolumeFraction scalar value # (value=value for liquid bridge volume in % of sum of surfaceLiquidContent of particles i and j) fix id all property/global capillaryTorqueCoeff scalar value # (value=value for the capillary torque coefficient, optional, default: 1.05; alternative name: capillaryTorqueCoefficient) fix id all property/global capillaryTorqueLimitFactor scalar value # (value=value for the capillary torque limit factor, optional, default: 0.13; alternative name: capillaryTorqueLimit) fix id all property/global capillaryTorquePowerLawIndex scalar value # (value=value for the capillary torque power-law index, optional, default: 0.45; alternative name: capillaryTorquePowerIndex)
Note
The capillary torque properties (capillaryTorqueCoeff, capillaryTorqueLimitFactor, and capillaryTorquePowerLawIndex) are optional. If omitted from the input script, default values based on Marshall (2014) are automatically applied.
For the scaling properties (scaleFactor, scalePowerIndex, and rpsFactor), refer to the gran scaling model documentation.
Symbol list#
\(b\): Liquid bridge radius (m)
\(A_T\), \(A_R\), \(c\), \(N\): Parameters for Washino power-law fluid viscous force model (-)
\(C\): Lumped coefficients for liquid bridge force components
\(\text{Ca}\): Capillary number (-)
\(f_{lb}\): Liquid bridge volume split factor (-)
\(f_{\text{limit}}\): Capillary torque limit factor (-)
\(\pmb{F}_{cap}\), \(\pmb{F}_{v,n}\), \(\pmb{F}_{v,t}\): Liquid bridge capillary, normal viscous and tangential viscous force (N)
\(\pmb{F}_{v,tq}\): Viscous force contributing to particle rotation (N)
\(h\): Liquid bridge immersion height (m)
\(H\): Distance between particle or particle-wall surfaces (function of \(a\)) (m)
\(K\): Flow consistency of power-law fluid (Pa.s^n)
\(m\): Capillary torque power-law index (-)
\(\pmb{M}_{\text{cap}}\): Torque due to capillary force (capillary rolling resistance) (N.m)
\(\pmb{M}_v\): Torque due to viscous force (N.m)
\(n\): Power-law fluid index (-)
\(\pmb{n}\): Unit normal vector between particle of particle-wall centres (-)
\(r\): Particle radius (m)
\(\overline{r}\): Particle or particle-wall reduced radius (m)
\(S\): Inter-particle or particle-wall separation distance (m)
\(S_{rup}\): Liquid bridge rupture distance (m)
\(\pmb{v}\): Particle translational velocity (m/s)
\(\pmb{v}_r\): Translational relative velocity (m/s)
\(V_l\): Particle surface liquid volume (m^3)
\(V_{lb}\): Liquid bridge volume (m^3)
\(V_{par}\): Particle volume (m^3)
\(\alpha\): Liquid bridge filling angle (rad)
\(\delta\): Inter-particle or particle-wall overlap (m)
\(\dot{\gamma}\): Liquid shear rate (1/s)
\(\theta\): Effective contact angle between solid and liquid (rad)
\(\lambda\), \(\chi\), \(\Omega\): Parameters for Washino power-law fluid viscous force model (-)
\(\mu\): Liquid viscosity (Pa.s)
\(\xi\): Capillary torque lever arm (m)
\(\sigma\): Liquid surface tension (N/m)
\(\phi_l\): Particle surface liquid volume flux (in % particle volume) (1/s)
\(\pmb{\omega}\): Particle rotational velocity (rad/s)
\(\pmb{\omega}_r\): Rotational relative velocity (rad/s)
\(\Delta_t\): Timestep (s)
Output#
This gran model stores a couple of per-particle properties for access by various output commands.
You can access the property surfaceLiquidContent by f_surfaceLiquidContent[0] (units % of particle volume), liquidFlux (units % of particle volume/time) by accessing f_liquidFlux[0] and liquidSource (units % of particle volume/time) by accessing f_liquidSource[0]. The set command can be used to manually set a surface liquid source or modify the surface liquid content during the simulation run.
Currently, there is a restriction that these properties can only be accessed after a run 0 command.
Restrictions#
The cohesion model is not available for atom_style superquadric.
The model can be used with fix wall/gran to compute the liquid bridge force between particle and wall. However, currently no surface liquid content information is stored by the wall and there is no liquid transfer between particle and wall when the liquid bridge breaks.
Default#
capillaryModel = capillaryNormalLambert (enabled by default if no capillary normal model is specified)
powerLawViscousNormalModel = powerLawViscousNormalWashino (enabled by default if no normal viscous model is specified)
powerLawViscousTangentModel = powerLawViscousTangentWashino (enabled by default if no tangential viscous model is specified)
liquidTransferModel = ‘off’
limitLiquidContent = ‘off’, modifyLbVolume = ‘off’ with lbVolumeFraction = 0.05, tangential_reduce = ‘off’
Global property defaults (if omitted from input script):
capillaryTorqueCoeff = 1.05
capillaryTorqueLimitFactor = 0.13
capillaryTorquePowerLawIndex = 0.45